Edmund Optics uses cookies to optimize and enhance the features and content on our website. By continuing to use this website, you consent to our use of cookies.

  • My Account
  •   

Test Targets

Test Targets are used to measure the accuracy or performance of an imaging system to ensure effective functioning. Test Targets are selections of slides or windows that are integrated into imaging systems to measure a number of imaging characteristics including resolution, distortion, or color/grayscale. Test Targets often feature an array of lines, dots, or other patterns which an imaging system focuses on in order to determine its level of precision. Test Targets allow imaging systems to maintain a high level of accuracy over time or multiple applications.

Edmund Optics offers a wide range of Test Targets suited for many imaging systems. Test Targets are designed to easily integrate into an imaging system for quick, easy setup. Test Targets may be used repeatedly with any number of different systems, allowing a small number of targets to service large numbers of imaging systems. Test Targets are available in glass, chrome, or photographic paper for multiple compatibility options for ease of use.

Resolution Test Targets | View All

High Resolution Microscopy Slide Targets New
×

High Resolution Microscopy Slide Targets
  • Small Pattern Sizes - 100nm and 3300 lp/mm
  • Composed using High-Precision E-Beam Lithography
  • Negative Pattern Design
1951 USAF Contrast Resolution Target
1951 USAF Contrast Resolution Target
  • 15 USAF Targets Which Vary in Density
  • Allows Resolution Measurements at Different Contrast Levels
1951 USAF Glass Slide Resolution Targets
1951 USAF Glass Slide Resolution Targets
  • Negative and Positive Patterns On Glass
  • Two Sizes Available
  • Each is Boxed and Includes Resolution Value Chart
  • High Resolution Target Available (down to 645 lp/mm)
1951 USAF Photographic Paper Resolution Targets
1951 USAF Photographic Paper Resolution Targets
  • Arranged on a 4:3 Aspect Ratio to Measure Resolution as a Function of Field
  • Each Section Contains Four USAF Targets of Varying Density Levels
Clear Optical Path USAF Target
Clear Optical Path USAF Target
  • Determine Resolution for X-Ray, UV, Thermal, and Far-IR Imaging Systems
  • Easy Mounting
  • Ideal for Transmittance Applications
High Precision Ronchi Rulings
High Precision Ronchi Rulings
  • Chrome on Glass
  • High Tolerance
  • Superior to Etched and Filled Rulings
  • Lines Parallel to Edge
  • English and Metric Versions
I3A/ISO Resolution Test Chart
I3A/ISO Resolution Test Chart
  • Complies with the ISO 12233 Standard
  • Offers Full Field Resolution Calibration
  • Applicable to Both Monochrome and Color Cameras that Deliver a Digital or Analog Video Signal
  • Three Sizes Available
IEEE Target
IEEE Target
  • Full Field Resolution Calibration
  • Designed for Testing of Analog Imaging Systems
NBS 1963A Resolution Target
NBS 1963A Resolution Target
  • Negative or Positive Patterns
  • Complies With NBS Standard 1010A
  • Frequency Range From 1-512 Cycles/mm
Opal Glass Ronchi Ruling Slides
Opal Glass Ronchi Ruling Slides
  • Chrome on Opal
  • Test Resolution of Reflective Systems
  • High Tolerance
Precision Ronchi Ruling Glass Slides
Precision Ronchi Ruling Glass Slides
  • Used for Evaluation of Resolution, Field Distortion, and Parfocal Stability
  • Ideal for Reticle and Field Calibration Requirements
  • Available on Float Glass, Fused Silica, Fused Silica with Fluorescent Backing, and Opal.
Precision Ronchi Rulings on Opal Glass
Precision Ronchi Rulings on Opal Glass
  • Chrome on Opal
  • High Tolerance
  • English and Metric Versions
Sinusoidal Targets
Sinusoidal Targets
  • Designed for MTF Testing
  • Determines Image Quality of Imaging Components
Star Target
Star Target
  • Ideal for Detection of Focus Errors and Astigmatism
  • 0.6 to 14 lp/mm Wedge Spacing
  • Available on White Photographic Paper or Chrome on Glass
Star Target Arrays
Star Target Arrays
  • Detect Aberrations at Various Field Points
USAF 1951 and Dot Grid Target
USAF 1951 and Dot Grid Target
  • USAF 1951 Elements 0 to 3 (14 lp/mm)
  • Fixed Frequency Grid on 2mm Centers
  • 2” x 2.75”
USAF Pattern Wheel Target
USAF Pattern Wheel Target
  • Tests Resolutions from 4 to 228 lp/mm
  • Ability to tests Multiple Field Points using 9 Targets
  • Reduces Testing Time
UV Fused Silica and Fluorescent USAF 1951 Resolution Targets
UV Fused Silica and Fluorescent USAF 1951 Resolution Targets
  • Designed for Calibration of UV or Fluorescence Microscopes
  • Fluorescent Targets have 365nm Excitation Wavelength, 550nm Emission Wavelength
  • Negative and Positive Targets Available
Variable Frequency Targets
Variable Frequency Targets
  • 5 lp/mm to 120 lp/mm or 5 lp/mm to 200 lp/mm
  • 1mm Wide Step Size
  • 5 lp/mm Step Increments
  • Used to Calibrate Video Systems
  • Inspect Unknown Resolutions

Distortion Test Targets | View All

Concentric Square Target
Concentric Square Target
  • For Calibration of Measurement Software
  • NIST Traceable Certificate of Accuracy Included
  • 1mm to 50mm Squares
Checkerboard Calibration Targets New
×

Checkerboard Calibration Targets
  • Chrome Pattern on Dimensionally Stable Glass Substrates
  • Optimized for Reflective Illumination Calibration of Imaging Systems
  • Various Sizes from 20mm for Small or Large Field of Views
Diffuse Reflectance Grid Distortion Targets
Diffuse Reflectance Grid Distortion Targets
  • Diffuse Reflectance Treatment Mimics Ceramic Targets
  • Chrome Pattern on Substrate
  • No Glare with On or Off Axis Lighting
  • Perfect for Front Illuminated Measuring
Fixed Frequency Grid Distortion Targets
Fixed Frequency Grid Distortion Targets
  • For Distortion Measurement and Calibration of Imaging Systems
  • Chrome on Soda Lime Glass or Chrome on White Ivory Glass Versions
  • NIST Certificate of Accuracy Included
Line Grid Target
Line Grid Target
  • Test and Correction of Distortion in Vision Systems
  • Calibration of Perspective Error in Microscope Stages
  • Measure Physical Field of View
Multi-Frequency Grid Distortion Targets
Multi-Frequency Grid Distortion Targets
  • For Calibration of Imaging Systems
  • Varying Spatial Frequency for Different Fields of View
  • NIST Certificate of Accuracy Included

Image Analysis Test Targets | View All

DOF 5-15 Depth of Field Target
DOF 5-15 Depth of Field Target
  • Test Depth of Field of Your Imaging System
  • Effective Measurement Eliminates the Need for Calculations
Dot and Square Calibration Target
Dot and Square Calibration Target
  • Designed for Measurement Calibration
  • Positive or Negative Chrome Patterns on Glass
  • High Contrast Target for Imaging with Elements from 0.5 to 10mm
  • NIST Traceability Certificate Included
Dual Axis Linear Scale Stage Micrometer
Dual Axis Linear Scale Stage Micrometer
  • Dual Axis Design
  • English and Metric Scales
  • NIST Certified Version Available
EO Machine Vision Stage Micrometers
EO Machine Vision Stage Micrometers
  • NIST Traceable Certificate of Accuracy Included
  • Ideal for Quick Calibration of Vision Systems
  • Durable Storage Case Included
EO Telecentricity Target
EO Telecentricity Target
  • Critical Tool for Measurement Vision Systems
  • Calibrates Any Type of Lens
  • Covers Large Range of Magnifications
Image Analysis Micrometer
Image Analysis Micrometer
  • Designed for Measurement Calibration
Kodak Imaging Chart
Kodak Imaging Chart
  • Over 18 Test Patterns
  • 8 ½" x 11" Film
Micro Line and Dot Standard Stage Micrometer
Micro Line and Dot Standard Stage Micrometer
  • New Opal Version Available
  • Calibrate Pixel Dithering
  • Lines and Dot Range from 2μm to 100μm
Multi-Function Calibration Target for Low Magnification Systems
Multi-Function Calibration Target for Low Magnification Systems
  • Calibrates Systems from 0.08X to 4X
  • Measures MTF, DOF, Resolution, FOV, and Distortion
  • NIST Certificate of Accuracy Included
Multi-Function High Magnification Calibration Targets
Multi-Function High Magnification Calibration Targets
  • Designed for Measurement Calibration; Ideal for Microscopes and Machine Vision Systems
  • Includes Ronchi Rulings, Concentric Circles, Square Grids, and a Linear Microscale
  • Two Targets Available for Different Magnifications
  • NIST Certificate of Accuracy Included
Multi-Grid Standard Stage Micrometer
Multi-Grid Standard Stage Micrometer
  • Calibrate Distortion in High Magnification Systems

Color and Gray Level Test Targets | View All

Color Checkers
Color Checkers
  • Test True Color Balance
  • Include Natural, Chromatic, Primary, and Gray Scale Colors
  • 24, 30, 50 or 140 Scientifically Designed Patches
Color Scanner Test Target
Color Scanner Test Target
  • Ideal for Evaluation of Color Flatbed Scanners
NIST Traceable Color Transmission Calibration Slides New
×

NIST Traceable Color Transmission Calibration Slides
  • 24 Calibrated Colors Patches
  • Patch Diameters from 150 to 4150µm
  • Compatible with Oil Immersion Objectives
EIA GrayScale Pattern Slide
EIA GrayScale Pattern Slide
  • Video Calibration
  • Permanent Density Standard
  • Evaluate/Compare the Dynamic Range of Cameras
ISO-14524 Reflective Camera Contrast Chart
ISO-14524 Reflective Camera Contrast Chart
  • Determines Dynamic Range of Cameras
  • 12 gray level patches
ISO-21550 Dynamic Range Film
ISO-21550 Dynamic Range Film
  • Used to Determine Optical Density Range of Transmission Scanners and Imaging Systems
Large Grayscale Target
Large Grayscale Target
  • 15 Density Steps
  • Logarithmic Grayscale
Reflective Scanner Test Target
Reflective Scanner Test Target
  • Complies with the ISO 16067-1 Standard
  • Designed to Test Digital Scanning Systems
Spectralon® White Balance and Diffuse Reflectance Targets
Spectralon® White Balance and Diffuse Reflectance Targets
  • Diffuse Reflectance with 99% Nominal Reflectance in UV-VIS-NIR Wavelength Range (350 - 1600nm)
  • Durable, Stable, and Washable
  • NIST Traceable Calibration Certificate and Data from 250 - 2500nm

×

Need a Quote?

Edmund Optics Facebook Edmund Optics Twitter Edmund Optics YouTube Edmund Optics LinkedIn Edmund Optics Instagram

Edmund Optics, Inc. BBB Business Review ISO Logo itar Logo
×